EU Cookie Law Script 1

     We use cookies to make our websites easier to use. By browsing our websites you agree to our use of cookies.

Video: Features der L-INX 7.0 Release

LINX-153/154 Automation Server

LINX-153

Index

Features

  • Programmable with L‑STUDIO IEC 61131‑3 and IEC 61499
  • Programmable with L‑LOGICAD 
  • Physical inputs and outputs with L‑IOB I/ O Modules (LIOB‑10x, LIOB‑15x, and LIOB‑45x/55x for LINX‑153) (LIOB‑45x/55x for LINX‑154)
  • 128x64 graphic display with backlight
  • Local and remote access to information about device status and data points
  • Manual operation using the jog dial or VNC client
  • Alarming, Scheduling, and Trending (AST™)
  • Node.js support for easy IoT integration (e.g. Google calendar, Alexa & friends, multimedia equipment,…)
  • Event-driven e-mail notification
  • Math objects to execute mathematical operations on data points
  • Stores customized graphical pages
  • Visualization of customized graphical pages through LWEB‑900 (Building Management), LWEB‑803 (Monitoring and Control), or LWEB‑802 (Web Browser)
  • Built-in OPC XML-DA and OPC UA server
  • Dual switched or separated Ethernet port
  • Access to network statistics
  • Compliant with ANSI/ASHRAE–135‑2012 and ISO 16484‑5:2012 standard
  • Supports BACnet MS/‌TP and BACnet/‌IP
  • BACnet Client Function (Write Property, Read Property, COV Subscription)
  • BACnet Client Configuration with configuration tool (scan and EDE import)
  • B-BC (BACnet Building Controller) functionality, BTL certified
  • Compliant with CEA‑709, CEA‑852, and ISO/‌IEC 14908 Standard (LonMark System)
  • Supports TP/‌FT‑10 (only LINX-153)
  • Support of dynamically created or static NVs
  • Support of user-defined NVs (UNVTs) and Configuration Properties (SCPTs, UCPTs)
  • Remote Network Interface (RNI) with 2 MNI devices (only LINX-153)
  • Integrated BACnet/‌IP to BACnet MS/‌TP Router including BBMD as well as Slave-Proxy functionality
  • Integrated IP‑852 to TP/FT‑10 Router(only LINX-153)
  • KNXnet/‌IP, connection to KNX TP1 through LKNX-300 Interface (only LINX-153)
  • M-Bus Master according to EN 13757-3, connection via optional M‑Bus Converter (only LINX-153)(L‑MBUS20 or L‑MBUS80)
  • Gateway functions including Smart Auto-Connect™
  • Modbus TCP and Modbus RTU (Master or Slave)
  • Integrated web server for device configuration and monitoring data points
  • Configurable via TP/FT‑10 (only LINX-153) or Ethernet/‌IP
  • Connection to EnOcean wireless devices via L-ENO Interface (only LINX-153)
  • Supports SMI (Standard Motor Interface) through LSMI-800 or LSMI-804 (only LINX‑153)
  • Supports MP-Bus through LMPBUS‑804 Interface (only LINX‑153)
  • Supports WLAN through LWLAN-800 Interface
  • Supports LTE through LTE-800 Interface
  • Stores user-defined project documentation