Software license, Software activation with costs for one PC, uses Ethernet port of PC to connect to a LonMark IP-852 channel
Floating licence via USB hardlock key, uses Ethernet port of PC to connect to a LonMark IP-852 channel
USB-Interface, connects to the USB port of a PC, supports LonMark TP/FT-10, TP/XF-1250, and TP/RS-485
Successor of NIC709-IP3E100, Remote network interface (RNI), PC connection via Ethernet/IP, Supports a LonMark TP/FT-10 channel
Remote network interface (RNI), PC connection via Ethernet/IP, Supports a LonMark TP/XF-1250 channel
LWEB-900-VPN-MNT, Enable adding/removing VPN clients in LWEB-900 for all projects. Valid for 1 year.
LWEB-900-VPN-BASE, Enable VPN support in LWEB-900 for one project. This license includes LWEB-900-VPN-MNT for 1 year.
LWEB-APP iOS - free download for iphone / ipad (App Store - iOS/iPadOS)
LWEB-APP, free download for Android smartphone / mobile phone / tablet (Google Play Store)
Building Management Software for an unlimited number of LOYTEC devices, licenses for 5 LWEB‑900 clients and 20 LWEB‑80x clients are included
Building Management Software Competence Partner Edition for an unlimited number of LOYTEC devices, licenses for 5 LWEB‑900 clients and 20 LWEB‑80x ...
Building Management Software for 10 LOYTEC devices, licenses for 5 LWEB-900 clients and 20 LWEB-80x clients are included
Graphical User Interface, visualization on Windows PC, free download
BACnet, CEA-709, and Modbus Touch Panel 7”, frameless glass front and capacitive touch, black
BACnet, CEA-709, and Modbus Touch Panel 7”, frameless glass front and capacitive touch, silver
BACnet, CEA-709, and Modbus Touch Panel with 15″ display, frameless glass front and capacitive touch, white
BACnet, CEA-709, and Modbus Touch Panel with 15″ display, frameless glass front and capacitive touch, black
BACnet, CEA-709, and Modbus Touch Panel with 15″ display, frameless glass front and capacitive touch, silver
BACnet, CEA-709, and Modbus Touch Panel 12”, frameless glass front and capacitive touch, white
BACnet, CEA-709, and Modbus Touch Panel 12.1”, frameless glass front and capacitive touch, black
BACnet, CEA-709, and Modbus Touch Panel 12”, frameless glass front and capacitive touch, silver
CEA-709, BACnet, and Modbus Touch Panel 7″, frameless glass front and capacitive touch, black
Network terminator, 1 x RS‑485 (bus topology, ANSI TIA/EIA-485) with biasing circuit (failsafe biasing)
Network terminator for: 1 x TP/FT-10 or TP/LPT-10 (bus or free topology), 1 x TP/XF-1250 (bus toplogy only)
Network terminator for 1 x RS‑485 (bus topology, ANSI TIA/EIA-485), 1 x Network Access Connector RJ45
Network terminator for 1 x TP/FT-10 or TP/LPT-10 (bus or free topology), 1 x Network Access Connector RJ45
LSTAT-802 based custom design, includes EnOcean interface, minimum quantity 100 pcs, enclosure G1: silver, G2: black, G3: white; custom print Lx, ...
LSTAT-800 based custom design, includes EnOcean interface, minimum quantity 100 pcs, enclosure G1: silver, G2: black, G3: white; custom print Lx, ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver, CO2,
Buttons ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver, CO2,
Buttons ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver, CO2,
Buttons ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver, CO2,
Buttons (L3): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver, CO2,
Buttons ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver, CO2,
Buttons ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver, CO2,
Buttons ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver, CO2,
Buttons (L3): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver, CO2,
Buttons (L2): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver, CO2,
Buttons (L1): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver, CO2,
Buttons (L2): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver, CO2,
Buttons (L1): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver,
Buttons (L6): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver,
Buttons (L5): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver,
Buttons (L4): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver,
Buttons (L3): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver,
Buttons (L6): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver,
Buttons (L5): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR reveiver,
Buttons (L4): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver,
Buttons (L3): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver,
Buttons (L2): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver,
Buttons (L1): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver,
Buttons (L2): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, occupancy, IR receiver,
Buttons (L1): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L6): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L5): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L4): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L3): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L6): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L5): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L4): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L3): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L2): ...
Room control unit, white front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L1): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L2): ...
Room control unit, black front, white enclosure, Modbus, temperature, rel. humidity, ext. switch/NTC, infrared receiver
Buttons (L1): ...
Bluetooth Mesh Room Controller for room segment, aisle, floor, building, or campus management
Mounting Socket, 24 V AC/DC input, 1x LonMark TP/FT-10 interface, 1 x RS-485 interface, black
Mounting Socket, 24 V AC/DC input, 1x LonMark TP/FT-10 interface, 1 x RS-485 interface
Mounting Socket, 24 V AC/DC input, 6 x relays 2 A 24 V, 7 x universal I/O (IO), 1 x RS-485 interface, black
Mounting Socket, 24 V AC/DC input, 6 x relays 2 A 24 V, 7 x universal I/O (IO), 1 x RS-485 interface, white
Programmable Touch Panel, Dual Ethernet, WLAN, Bluetooth, proximity sensor, temperature and humidity sensor, illuminance sensor, IR receiver, BACnet, ...
Programmable Touch Panel, Dual Ethernet, WLAN, Bluetooth, proximity sensor, temperature and humidity sensor, illuminance sensor, IR receiver, BACnet, ...
Programmable Touch Panel, Dual Ethernet, WLAN, Bluetooth, proximity sensor, temperature and humidity sensor, illuminance sensor, IR receiver, BACnet, ...
Programmable Touch Panel, Dual Ethernet, WLAN, Bluetooth, proximity sensor, temperature and humidity sensor, illuminance sensor, IR receiver, BACnet, ...
Touch Panel, Dual Ethernet, WLAN, Bluetooth, proximity sensor, temperature and humidity sensor, illuminance sensor, IR receiver, black front, black ...
Touch Panel, Dual Ethernet, WLAN, Bluetooth, proximity sensor, temperature and humidity sensor, illuminance sensor, IR receiver, white front
Set contains: Network Interface NIC709-USB100, and Protocol Analyzer Software LPA-SW for CEA‑709 channels, registered to NIC709-USB100
Set contains: Network Interface NIC709-USB100 and NIC852, Protocol Analyzer Software LPA-IP-SW for IP-852 channels, supports remote LPA, registered ...
Protocol Analyzer Software for IP-852 channels, supports Remote LPA functionality, NIC852 not included
IP-852 Channel Protocol Analyzer Bundle contains: Network Interface NIC852, Protocol Analyzer Software LPA-IP-SW for IP-852 channels, supports remote ...
Learn how to install, commission and parameterize L-ROC devices in an L-ROC projects (online training, free of charge)
Class training - Learn how to implement L-ROC projects including project planning, programming and installation of all devices
LOYMS2-OW-B, On-wall Surface Mounting Box Kit for LDALI-MS2-BT-B / LOYBT-MS2-B, black (8 boxes per package), black (expected availability Q2 2025)
LOYMS2-OW, On-wall Surface Mounting Box Kit for LDALI-MS2-BT / LOYBT-MS2 (8 boxes per package), white
Bluetooth SIG Mesh qualified multi-sensor (presence detection, lux sensor, IR receiver, temperature sensor, humidity sensor, 3 digital inputs, ...
Bluetooth SIG Mesh qualified multi-sensor (presence detection, lux sensor, IR receiver, temperature sensor, humidity sensor, 3 digital inputs, ...
Bluetooth SIG Mesh qualified multi-sensor (presence detection, lux sensor, IR receiver, temperature sensor, humidity sensor, 3 digital inputs, ...
Bluetooth SIG Mesh qualified multi-sensor (presence detection, lux sensor, IR receiver, temperature sensor, humidity sensor, 3 digital inputs, ...
Bluetooth SIG Mesh qualified multi-sensor (presence detection, lux sensor, IR receiver, temperature sensor, humidity sensor, 3 digital inputs, ...
Successor of LIP-ME201, BACnet/IP Router, 1 x BACnet MS/TP (RS-485), 2 x Ethernet Port (BACnet/IP)
L-IOB I/O Controller: 8x Universal I/O (IO), 7x Digital Output (DO) (5x Relay 2A, 2x Relay 6A)
L-IOB I/O Controller: 8 x Universal I/O (U, I, R), 8 x Universal I/O (U), 7x Digital Output (DO) (5x Relay 2A, 2x Relay 6A)
L-IOB Room Controller, 8x Universal I/O (U, I, R), 12x Universal I/O (U), 1x TRIAC 1250W, 3x TRIAC 300W
I/O Controller, 6 UI, 4 DI, 6 DO (6 x Relay 10 A Type2), 6 channel power measurement built-in
LIOB-IP852 I/O Module: 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 0.5 A), 1 Pressure Sensor