Video: Features der L-INX 7.0 Release

LINX-153/154 Automation Server

LINX-153
CEA-709BACnetKNXM-BusMP-BusModbusOPC XML-DAOPC UAEnOceanSMIWireless Local Area Network (WLAN)LTESNMPAlarming (Alarm Management)SchedulingTrending (Historic Data Logging)IoTE-mail NotificationSMS NotificationEthernet (Ethernet Switch)LIOB-ConnectLIOB-FTLIOB-IPGateway FunctionLocal ConnectionGlobal ConnectionLocal Manual OperationNetwork SecurityRemote AccessVNC (Virtual Network Computing)Remote Network Interface (RNI)Web Server for Device ConfigurationMathematical FunctionsIEC 61131 – L-LOGICADCEA-709 Router FunctionBACnet Router FunctionBackup / RestoreLWEB-900 Integrated Building Management SystemLWEB-802/803 VisualizationIEC 61499 – L-STUDIOIEC 61131 – L-STUDIOBTL-Certified Product

Index

The L‑INX Automation Servers LINX‑153 and LINX‑154 are powerful, programmable automation stations, which can be programmed by L‑STUDIO. The L‑INX Automation Servers can host user specific graphical pages and can integrate physical I/ Os through L‑IOB I/ O Modules via LIOB‑Connect, LIOB‑FT, or LIOB‑IP. The LINX‑154 can only be extended by LIOB‑IP. Local operation and override is provided by the built-in jog dial and the backlit display (128x64 pixels). Device and data point information is shown on the display via symbols and in text format.

The powerful Automation Servers provide connectivity functions to concurrently integrate CEA‑709 (LonMark Systems), BACnet, KNX, Modbus, and M‑Bus subsystems. LonMark Systems can be integrated via IP‑852 (Ethernet/ IP) or TP/ FT‑10. BACnet integration is supported through BACnet/ IP (Ethernet/ IP) or BACnet MS/ TP (RS‑485). LINX‑153 Automation Servers feature an integrated Remote Network Interface (RNI) to access the TP/ FT‑10 channel on the device via Ethernet/ IP. LINX‑153 Automation Servers feature two built-in routers, one IP‑852 router and one BACnet/ IP to MS/ TP router including BBMD as well as Slave-Proxy functionality providing the complete feature set of the corresponding L-IP devices.

The LINX‑153 and LINX‑154 implement the BACnet Building Controller (B-BC) profile and are BTL certified. In addition, the LINX‑15x provide connectivity to KNXnet/ IP (only LINX‑153) and Modbus TCP via Ethernet/ IP and to Modbus RTU via RS‑485. M‑Bus and KNX TP1 (only for LINX‑153) device integration needs optional interface modules.

The gateway functionality allows data communication between all communication technologies available on the device. Different technology data points are mapped through Local Connections on the device. The mapping of different technology data points on distributed devices is supported by Global Connections. L‑INX Automation Servers also support Smart Auto-Connect™ – the automatic generation of connections to substantially reduce engineering efforts and cost. All technology data points are automatically created as OPC XML‑DA and OPC UA data points.

Each L‑INX Automation Server is equipped with two Ethernet ports. It can either be configured to use the internal switch to interconnect the two ports or every port is configured to work in a separate IP network.

When the Ethernet ports are configured for two separate IP networks, one port can be connected for instance to a WAN (Wide Area Network) with enabled network security (HTTPS) while the second port can be configured to be connected to an insecure network (LAN) where the standard building automation protocols like BACnet/ IP, LON/ IP, or Modbus TCP are present. These devices also feature firewall functionality of course to isolate particular protocols or services between the ports.The built-in VPN function provides for simple VPN setup and secure access to remote sites. The LTE-800 interface enables wireless access to remote sites through a mobile carrier.

Using the internal switch, a daisy chained line topology of up to 20 devices can be built, which reduces costs for network installation. The IP switch also allows the setup of a redundant Ethernet installation (ring topology), which increases reliability. The redundant Ethernet topology is enabled by the Rapid Spanning Tree Protocol (RSTP), which is supported by most managed switches.

The L‑INX devices provide fully featured AST™ functionality (Alarming, Scheduling, and Trending) and can be integrated perfectly into the L‑WEB System.

IoT Integration

The IoT function (Node.js) allows connecting the system to almost any cloud service, either for uploading historical data to analytics services, delivering alarm messages to alarm processing services or operating parts of the control system over a cloud service (e.g., scheduling based on Web calendars or booking systems). Processing Internet information such as weather data in forecast-based control is also possible. Finally, the JavaScript kernel also allows implementing serial protocols to non-standard equipment in primary plant control.

 

linx anlagenbild 153

LINX-153/154 Automation Server Products


LINX-153
LINX-153

BACnet & CEA‑709 Automation Server with LIOB‑Connect and 61131-3 programming in L-STUDIO

Add this product to the Request for Quote
Related documents and software for LINX-153
3D View for LINX-153

LINX-154
LINX-154BACnet Automation Server with 4 RS-485 channels
Add this product to the Request for Quote
Related documents and software for LINX-154
3D View for LINX-154

LIOB-A2
LIOB-A2

L‑IOB Adapter 2 to split the LIOB‑Connect bus using 4-wire cables

Add this product to the Request for Quote
Related documents and software for LIOB-A2
3D View for LIOB-A2

LIOB-A4
LIOB-A4

L‑IOB Adapter 4 to split the LIOB‑Connect bus using RJ45 network cables

Add this product to the Request for Quote
Related documents and software for LIOB-A4
3D View for LIOB-A4

LIOB-A5
LIOB-A5

L‑IOB Adapter 5 to terminate the LIOB-Connect bus

Add this product to the Request for Quote
Related documents and software for LIOB-A5
3D View for LIOB-A5

LIOB-100
LIOB-100

LIOB-Connect I/O Module: 8 UI, 2 DI, 2 AO, 9 DO (5 x Relay 6 A, 4 x Triac 0.5 A)

Add this product to the Request for Quote
Related documents and software for LIOB-100
3D View for LIOB-100

LIOB-101
LIOB-101

LIOB-Connect I/O Module: 8 UI, 16 DI

Add this product to the Request for Quote
Related documents and software for LIOB-101
3D View for LIOB-101

LIOB-102
LIOB-102

LIOB-Connect I/O Module: 6 UI, 6 AO, 8 DO (8 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-102
3D View for LIOB-102

LIOB-103
LIOB-103

LIOB-Connect I/O Module: 6 UI, 6 AO, 5 DO (5 x Relay 16 A)

Add this product to the Request for Quote
Related documents and software for LIOB-103
3D View for LIOB-103

LIOB-150
LIOB-150

LIOB-FT I/O Module: 8 UI, 2 DI, 2 AO, 8 DO (4 x Relay 6 A, 4 x Triac 0.5 A)

Add this product to the Request for Quote
Related documents and software for LIOB-150
3D View for LIOB-150

LIOB-151
LIOB-151

LIOB-FT I/O Module: 8 UI, 12 DI

Add this product to the Request for Quote
Related documents and software for LIOB-151
3D View for LIOB-151

LIOB-152
LIOB-152

LIOB-FT I/O Module: 6 UI, 6 AO, 8 DO (8 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-152
3D View for LIOB-152

LIOB-153
LIOB-153

LIOB-FT I/O Module: 6 UI, 6 AO, 5 DO (4 x Relay 16 A, 1 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-153
3D View for LIOB-153

LIOB-154
LIOB-154

LIOB-FT I/O Module: 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 0.5 A), 1 Pressure Sensor

Add this product to the Request for Quote
Related documents and software for LIOB-154
3D View for LIOB-154

LIOB-450
LIOB-450

LIOB-IP852 I/O Module: 8 UI, 2 DI, 2 AO, 8 DO (4 x Relay 6 A, 4 x Triac 0.5 A)

Add this product to the Request for Quote
Related documents and software for LIOB-450
3D View for LIOB-450

LIOB-451
LIOB-451

LIOB-IP852 I/O Module: 8 UI, 12 DI

Add this product to the Request for Quote
Related documents and software for LIOB-451
3D View for LIOB-451

LIOB-452
LIOB-452

LIOB-IP852 I/O Module: 6 UI, 6 AO, 8 DO (8 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-452
3D View for LIOB-452

LIOB-453
LIOB-453

LIOB-IP852 I/O Module: 6 UI, 6 AO, 5 DO (4 x Relay 16 A, 1 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-453
3D View for LIOB-453

LIOB-454
LIOB-454

LIOB-IP852 I/O Module: 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 0.5 A), 1 Pressure Sensor

Add this product to the Request for Quote
Related documents and software for LIOB-454
3D View for LIOB-454

LIOB-550
LIOB-550

LIOB-BIP I/O Module: 8 UI, 2 DI, 2 AO, 8 DO (4 x Relay 6 A, 4 x Triac 0.5 A)

Add this product to the Request for Quote
Related documents and software for LIOB-550
3D View for LIOB-550

LIOB-551
LIOB-551

LIOB-BIP I/O Module: 8 UI, 12 DI

Add this product to the Request for Quote
Related documents and software for LIOB-551
3D View for LIOB-551

LIOB-552
LIOB-552

LIOB-BIP I/O Module: 6 UI, 6 AO, 8 DO (8 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-552
3D View for LIOB-552

LIOB-553
LIOB-553

LIOB-BIP I/O Module: 6 UI, 6 AO, 5 DO (4 x Relay 16 A, 1 x Relay 6 A)

Add this product to the Request for Quote
Related documents and software for LIOB-553
3D View for LIOB-553

LIOB-554
LIOB-554

LIOB-BIP I/O Module: 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 0.5 A), 1 Pressure Sensor

Add this product to the Request for Quote
Related documents and software for LIOB-554
3D View for LIOB-554

LPOW-2415A
LPOW-2415A

LIOB-Connect Power Supply, 24 VDC, 15 W

Add this product to the Request for Quote
Related documents and software for LPOW-2415A
3D View for LPOW-2415A

LPOW-2415B
LPOW-2415B

Power supply unit with power connector 24 VDC, 15 W

Add this product to the Request for Quote
Related documents and software for LPOW-2415B
3D View for LPOW-2415B

LPOW-2460B
LPOW-2460BPower supply unit with power connector 24 V DC, 60 W
Add this product to the Request for Quote
Related documents and software for LPOW-2460B
3D View for LPOW-2460B

L-MBUS20
L-MBUS20

M-Bus level converter for 20 M-Bus devices

Add this product to the Request for Quote
Related documents and software for L-MBUS20
3D View for L-MBUS20

L-MBUS80
L-MBUS80

M-Bus level converter for 80 M-Bus devices

Add this product to the Request for Quote
Related documents and software for L-MBUS80
3D View for L-MBUS80

LKNX-300
 

KNX interface to connect KNX TP1 devices

Add this product to the Request for Quote
Related documents and software for LKNX-300
3D View for LKNX-300

LENO-800
LENO-800

EnOcean Interface 868 MHz Europe

Add this product to the Request for Quote
Related documents and software for LENO-800
3D View for LENO-800

LENO-801
LENO-801

EnOcean Interface 902 MHz USA/Canada

Add this product to the Request for Quote
Related documents and software for LENO-801
3D View for LENO-801

LENO-802
LENO-802

EnOcean Interface 928 MHz Japan

Add this product to the Request for Quote
Related documents and software for LENO-802
3D View for LENO-802

LWLAN-800
LWLAN-800

Wireless LAN Interface IEEE 802.11bgn

Add this product to the Request for Quote
Related documents and software for LWLAN-800
3D View for LWLAN-800

LMPBUS-804
LMPBUS-804 MP-Bus Interface for 16 devices per channel, up to 4 channels
Add this product to the Request for Quote
Related documents and software for LMPBUS-804
3D View for LMPBUS-804

LSMI-800
LSMI-800Standard Motor Interface for 16 motors via EXT port
Add this product to the Request for Quote
Related documents and software for LSMI-800
3D View for LSMI-800

LSMI-804
LSMI-804Standard Motor Interface for 64 motors, 4 SMI channels via USB
Add this product to the Request for Quote
Related documents and software for LSMI-804
3D View for LSMI-804


Features

  • Programmable with L‑STUDIO IEC 61131‑3 and IEC 61499
  • Programmable with L‑LOGICAD 
  • Physical inputs and outputs with L‑IOB I/ O Modules (LIOB‑10x, LIOB‑15x, and LIOB‑45x/55x for LINX‑153) (LIOB‑45x/55x for LINX‑154)
  • 128x64 graphic display with backlight
  • Local and remote access to information about device status and data points
  • Manual operation using the jog dial or VNC client
  • Alarming, Scheduling, and Trending (AST™)
  • Node.js support for easy IoT integration (e.g. Google calendar, Alexa & friends, multimedia equipment,…)
  • Event-driven e-mail notification
  • Math objects to execute mathematical operations on data points
  • Stores customized graphical pages
  • Visualization of customized graphical pages through LWEB‑900 (Building Management), LWEB‑803 (Monitoring and Control), or LWEB‑802 (Web Browser)
  • Built-in OPC XML-DA and OPC UA server
  • Dual switched or separated Ethernet port
  • Access to network statistics
  • Compliant with ANSI/ASHRAE–135‑2012 and ISO 16484‑5:2012 standard
  • Supports BACnet MS/‌TP and BACnet/‌IP
  • BACnet Client Function (Write Property, Read Property, COV Subscription)
  • BACnet Client Configuration with configuration tool (scan and EDE import)
  • B-BC (BACnet Building Controller) functionality, BTL certified
  • Compliant with CEA‑709, CEA‑852, and ISO/‌IEC 14908 Standard (LonMark System)
  • Supports TP/‌FT‑10 (only LINX-153)
  • Support of dynamically created or static NVs
  • Support of user-defined NVs (UNVTs) and Configuration Properties (SCPTs, UCPTs)
  • Remote Network Interface (RNI) with 2 MNI devices (only LINX-153)
  • Integrated BACnet/‌IP to BACnet MS/‌TP Router including BBMD as well as Slave-Proxy functionality
  • Integrated IP‑852 to TP/FT‑10 Router(only LINX-153)
  • KNXnet/‌IP, connection to KNX TP1 through LKNX-300 Interface (only LINX-153)
  • M-Bus Master according to EN 13757-3, connection via optional M‑Bus Converter (only LINX-153)(L‑MBUS20 or L‑MBUS80)
  • Gateway functions including Smart Auto-Connect™
  • Modbus TCP and Modbus RTU (Master or Slave)
  • Integrated web server for device configuration and monitoring data points
  • Configurable via TP/FT‑10 (only LINX-153) or Ethernet/‌IP
  • Connection to EnOcean wireless devices via L-ENO Interface (only LINX-153)
  • Supports SMI (Standard Motor Interface) through LSMI-800 or LSMI-804 (only LINX‑153)
  • Supports MP-Bus through LMPBUS‑804 Interface (only LINX‑153)
  • Supports WLAN through LWLAN-800 Interface
  • Supports LTE through LTE-800 Interface
  • Stores user-defined project documentation


Tutorials

Features of L-INX 7.0 Release [LINX 7.0]

This video presents some new features of the L-INX 7.0 Release.

How to create schedulers (CEA-709) [A001]

This tutorial describes how to create schedulers on an L-VIS Touch Panel with the configuration tool L-VIS Configurator.

How to create a calendar including exception days (CEA-709) [A002]

This tutorial describes how to create a calendar including exception days on an L-VIS Touch Panel with the configuration tool L-VIS Configurator.

How to operate a scheduler on the web interface of a L-INX Automation Server [A004]

This tutorial describes how to use the Web UI of the LINX-101 Automation Server.

How to create a remote scheduler (CEA-709) [A005]

This tutorial describes how to create a remote scheduler on the LINX-101 Automation Server with the configuration tool NL220 LonWorks© Manager.

How to create alarms (CEA-709) [A006]

This tutorial describes how to create alarms on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to use e-mail configuration [A007]

This tutorial describes how to configure the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to create trend objects [A008]

This tutorial describes how to create trend objects on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to create schedulers on BACnet devices [A201]

This tutorial describes how to create schedulers on BACnet devices on the LINX-200 Automation Server with the configuration tool L-INX Configurator.

How to create a calendar on BACnet devices [A202]

This tutorial describes how to create a calendar on the LINX-200 Automation Server with the configuration tool L-INX Configurator.

How to create a remote scheduler on BACnet devices [A205]

This tutorial describes how to create a remote scheduler on the LINX-200 Automation Server with the configuration tool L-INX Configurator.

How to create alarms on BACnet devices [A206]

This tutorial describes how to create alarms on the LINX-200 Automation Server with the configuration tool L-INX Configurator.

How to create static network variables [B001]

This tutorial describes how to create static network variables on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to create dynamic network variables [B002]

This tutorial describes how to create dynamic network variables on the LINX-101 Automation Server with the configuration tool NL220 LonWorks© Manager.

How to create network variables by using LNS scan [B003]

This tutorial describes how to create network variables by using LNX scan on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to create network variables by using network scan [B004]

This tutorial describes how to create network variables by using network scan on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to import network variables by using CSV file import [B005]

This tutorial describes how to import network variables by using CSV file import on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to import extern network variables (LNS scan or network scan) [B006]

This tutorial describes how to import extern network variables on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

How to create network variables by using Filter Templates [B007]

This tutorial describes how to create network variables by using Filter Templates on the LINX-101 Automation Server with the configuration tool L-INX Configurator.

Manual creation of BACnet Server Objects [B201]

This tutorial describes how to create BACnet Server Objects manually on the LINX-200 Automation Server with the configuration tool L-INX Configurator.

How to create client mappings using network scan [B202]

This tutorial describes how to create client mappings using network scan on the LINX-200 Automation Server with the configuration tool L-INX Configurator.

How to create client mappings using EDE file import [B203]

This tutorial describes how to configure the LINX-200 Automation Server with the configuration tool L-INX Configurator.

Quick start scenario creating an L-WEB project [W001]

This tutorial describes how to create an L-WEB project and configure the LINX-101 Automation Server with the configuration tool L-INX Configurator.

A quick start scenario creating an L-WEB database [W002]

This tutorial describes how to create a database with the LWEB-801 Server and the configuration tool L-INX Configurator on the example of configuring the LINX-100 Automation Server.

How to create data points using M-Bus Network Scan [L001]

This tutorial describes how to create data points using M-Bus Network Scan on the LINX-100 Automation Server with the configuration tool L-INX Configurator.

How to create and use M-Bus device templates [L002]

This tutorial describes how to create and use M-Bus device templates on the LINX-100 Automation Server with the configuration tool L-INX Configurator.


Specification

Dimensions in mm [inch]

LINX-153

LINX-153_dimensions

 

Specifications LINX-153
Dimensions (mm) 159 x 100 x 75 (L x W x H), DIM053
Installation DIN rail mounting following DIN 43880, top hat rail EN 50022
Power supply 24 VDC / 24 VAC ±10 %, typ. 2.5 W
Operating conditions 0 °C to 50 °C, 10 – 90 % RH, non condensing, degree of protection: IP40, IP20 (terminals)
Interfaces

2 x Ethernet (100Base-T):
OPC XML‑DA, OPC UA,
LonMark IP‑852,
BACnet/ IP,
LIOB‑IP,
KNXnet/ IP,
Modbus TCP (Master or Slave),
HTTP, FTP, SSH, HTTPS,
Firewall, VNC, SNMP
1 x LIOB‑Connect
1 x TP/ FT‑10 (LonMark System)
1 x LIOB‑FT

2 x RS‑485 (ANSI TIA/ EIA‑485):
BACnet MS/ TP
or
Modbus RTU (Master or Slave)
2 x EXT:
M‑Bus, Master EN 13757‑3 (needs L‑MBUS20 or L‑MBUS80)
or
KNX TP1 (needs LKNX‑300)
or
SMI (needs LSMI-800)
2 x USB-A:
WLAN (needs LWLAN‑800),
EnOcean (needs LENO‑80x),
SMI (needs LSMI-804),
MP-BUS (needs LMPBUS-804), LTE (needs LTE-800)

L‑IOB I/O Modules Up to 24 L‑IOB I/ O Modules in any combination of type LIOB‑10x, LIOB‑15x, and LIOB‑45x/55x
Remote Network Interface 1 RNI with 2 MNI devices
BACnet/IP Router 1
CEA‑709 Router 1
Program cycle time Down to 10 ms
Specifications LINX-154
Dimensions (mm) 159 x 100 x 75 (L x W x H), DIM054
Installation DIN rail mounting following DIN 43880, top hat rail EN 50022
Power supply 24 VDC / 24 VAC ±10 %, typ. 2.5 W
Operating conditions 0 °C to 50 °C, 10 – 90 % RH, non condensing, degree of protection: IP40, IP20 (terminals)
Interfaces

2 x Ethernet (100Base-T):
OPC XML‑DA, OPC UA,
LonMark IP‑852,
BACnet/ IP,
LIOB‑IP,
Modbus TCP (Master or Slave),
HTTP, FTP, SSH, HTTPS,
Firewall, VNC, SNMP

4 x RS‑485 (ANSI TIA/ EIA‑485):
BACnet MS/ TP
or
Modbus RTU (Master or Slave)
2 x USB-A:
WLAN (needs LWLAN‑800), LTE (needs LTE-800)

L‑IOB I/O Modules Up to 24 L‑IOB I/ O Modules in any combination of type LIOB‑45x/55x
BACnet/IP Router 1
Program cycle time Down to 10 ms
Runtime licences
Type LINX-153 LINX-154
Programming, Tools L‑STUDIO (IEC 61131‑3 and IEC 61499 based), L‑INX Configurator
Licence

L‑STUDIO: included
L‑LOGICAD: included

L‑STUDIO: included
L‑LOGICAD: included

Resource limits LINX-153
Total number of data points 30 000 LonMark Scheduler 100
OPC data points 10 000 LonMark Alarm Server 1
BACnet objects 2 000 (analog, binary, multi-state) E-mail templates 100
BACnet client mappings 5 000 Math objects 100
BACnet calendar objects 25 Alarm logs 10
BACnet scheduler objects 100 (64 data points per object) M-Bus data points 1 000
BACnet notification classes 32 Modbus data points 2 000
Trend logs (BACnet or generic) 512 (4 000 000 logs, ≈ 60 MB) MP-Bus devices (per channel) 16
Total trended data points 1 000 KNX TP1 data points 1 000
CEA‑709 network variables (NVs) 2 000 KNXnet/IP data points 1 000
CEA‑709 Alias NVs 2 000 Connections (Local / Global) 2 000 / 250
CEA‑709 External NVs (polling) 2 000 Number of L-WEB clients 32 (simultaneously)
CEA‑709 address table entries 1 000 („non-ECS mode“: 15) L-IOB I/O Modules 24
LonMark Calendar 1 (25 calendar patterns) Number of EnOcean devices 100
SMI devices (per channel) 16 EnOcean data points 1 000
Resource limits LINX-154
Total number of data points 30 000 CEA‑709 address table entries 1 000 („non-ECS mode“: 15)
OPC data points 10 000 LonMark Calendar 1 (25 calendar patterns)
BACnet objects 2 000 (analog, binary, multi-state) LonMark Scheduler 100
BACnet client mappings 5 000 LonMark Alarm Server 1
BACnet calendar objects 25 E-mail templates 100
BACnet scheduler objects 100 (64 data points per object) Math objects
100
BACnet notification classes 32 Alarm logs 10
Trend logs (BACnet or generic) 512 (4 000 000 logs, ≈ 60 MB) Modbus data points 5 000
Total trended data points 1 000 Connections (Local / Global) 2 000 / 250
CEA‑709 network variables (NVs) 2 000 Number of L-WEB clients 32 (simultaneously)
CEA‑709 Alias NVs 2 000 L-IOB I/O Modules 24
CEA‑709 External NVs (polling) 2 000