LINX-110 Automation Server CEA-709 IEC 61131-3 Programmable Print

The high performance and freely programmable L-INX Automation Server LINX-110 and LINX-111 are used for control applications in building automation.

Use provides multi-faceted control environment. The built-in PLC functionality (IEC 61131-3) provides a high level of programming freedom. Programming is done with the L-logiCAD programming tool. The programming tool is based on the IEC 61131-3 standard and offers a number of programming languages including Function Block Diagram (FBD), Sequential Function Chart (SFC), Structured Text (ST), Ladder Logic and C.

The L-logiCAD programming tool allows online testing of the IEC61131-3 application over the building network. New IEC 61131-3 applications can be downloaded onto the device without interrupting the current program execution. Multiple IEC 61131-3 programs can be executed in parallel with different cycle times down to 10 ms. 

Different freely programmable Automation Servers for integrating in LonMark® systems (LINX-110 and LINX-111) are available. Communication is available on IP-852 (Ethernet) or on twisted-pair channel TP/FT-10.

CEA-709 (LonMark®, DIN EN 14908, ISO/IEC 14908)

linx-11x_schema_385x360.png

L-INX TypeRemote
Network Interface
Router
IP-852 to TP/FT-10
LINX-110
LINX-111
logicad_200.jpg

Commissioning and data point definition is done by the LINX-110/210 Configurator. Defined Data points coming from different technologies (CEA-709, Modbus, M-Bus) can be processed by the L-logiCAD programming tool.

The configuration tool offers a consistent philosophy regarding the handling and operation of the different types of Automation Server and communication technologies (see Data Point Manager under Additional Information for details). The LINX-110/210 Configurator is a free download from the LOYTEC web site.

The figure below shows the concept of mapping data points from CEA-709 (LonMark systems) to IEC 61131-3 data points:

linx110_210_concept_709.gif

Common Features:

 

  • IEC 61131-3 function block, structured text and ladder logic programming
  • Online testing via RS-232, Ethernet (TCP/IP), or CEA-709 network (TP/FT-10)
  • Offline simulation
  • Traceability of IEC 61131-3 variables via the L-logiCAD programming tool
  • Program download without interruption of the currently executed application program
  • New program download in the field via LINX-110/210 configuration tool or the web interface
  • Unicode support for IEC 61131-3 project documentation
  • Supports trending, scheduling, and alarming (AST™)
  • E-mail notification
  • SNTP support for time synchronization
  • Built-in Web server for device configuration and data point monitoring
  • Built-in communication test
  • Status and activity LED
  • IEC 61131-3 status LED
  • Network statistics information
  • M-Bus Master to integrate M-Bus devices according to EN 13757-3
  • Modbus Master to integrate Modbus devices (TCP, RTU)
  • Modbus Slave (TCP, RTU)
  • 12-35 V DC / 12-24 V AC supply voltage, typ. 3 Watt
  • 107 x 100 x 65 (L x W x H in mm) i.e. 6 TE
  • DIN-rail mountable

arrowRead more... (L-logiCAD IEC 61131-3)

L-INX Automation Server Products

LINX-110
LINX-110
  • L-INX Automation Server (CEA-709)
  • IEC 61131-3 programming languages (FBD, ST, LD/KOP, SFC, C)
  • Fully compliant with CEA-709, CEA-852 and EN 14908
  • Fully featured Remote Network Interface function with 2 MNI devices
  • Supports up to 1000 CEA-709 network variables
  • Supports up to 1000 address table entries
  • Support of dynamically created network variables or static network variables
  • Support of User Defined NVs (UNVTs) and Configuration Properties (SCPTs, UCPTs)
  • Maps SNVTs to IEC61131-3 variables
  • Convertion between different SNVT types
  • M-Bus Master (EN 13757-3)
  • Modbus Master/Slave
  • 2 Ports: 1 x TP/FT-10, 1 x Ethernet Port (IP-852) (user selectable)
  • 107 x 100 x 75 (L x W x H in mm)

Go to download page

LINX-111
LINX-111
  • L-INX Automation Server (CEA-709)
  • IEC 61131-3 programming languages (FBD, ST, LD/KOP, SFC, C)
  • Fully compliant with CEA-709, CEA-852 and EN 14908
  • Fully featured CEA-709/IP Router (TP/FT-10 / IP-852)
  • Supports up to 1000 CEA-709 network variables
  • Supports up to 1000 address table entries
  • Support of dynamically created network variables or static network variables
  • Support of User Defined NVs (UNVTs) and Configuration Properties (SCPTs, CPTs)
  • Maps SNVTs to IEC61131-3 variables
  • Convertion between different SNVT types
  • M-Bus Master (EN 13757-3)
  • Modbus Master/Slave
  • 2 Ports: 1 x TP/FT-10, 1 x Ethernet Port (IP-852) (user selectable)
  • 107 x 100 x 75 (L x W x H in mm)

Go to download page

L-LOGICAD
L-LOGICAD IEC 61131-3 Programming Tool

The Programming Tool L-LOGICAD is protected with a Softlock License. The Softlock License is part of the LINX-START-LC2 or LINX-START-BC2 Starter-Kit.
Computer Requirements using Softlock License:
Windows 2000/XP Professional/Vista Business,
must not be operated in a virtual machine/session (Windows Terminal Server Remote Session, VMWare, etc.),
Windows must be installed on a local harddisk with NTFS file system (no FAT32),
user must be logged on as "power user".


Go to download page

LINX-START-LC2
LINX-START-LC2 The L-INX Starter-Kit contains

  • 1 x LINX-110
  • 1 x L-logiCAD Softlock License for up to three PC's
  • 1 x LINX-100
  • 1 x LWEB-800

Go to download page