LIOB-18X/4XX - I/O Modules & Controllers 2.2.3 ============================================== Version String: Tue Oct 2 15:22:19 2012 - V2.2.3 LIOB-18X/4XX are LOYTEC products (www.loytec.com) ------------------------------------------------- !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! ATTENTION !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Older firmware versions (before version 2.2.3) must first be updated to version 2.2.3, before they can be updated to even higher versions. A version 2.2.1 for example must be updated to version 2.2.3 before it can be updated to version 4.X.Y. 1 Notes and Requirements ======================== LIOB-45X I/O modules expand LOYTEC devices providing a LIOB-IP channel (L-INX Automation Servers and L-ROC Room Controllers) with physical inputs and outputs. They can also be used as stand-alone LONMARK(R) certified devices. LIOB-18X/48X I/O controllers are application specific controllers with all required I/Os on-board. This firmware can be used for: - LIOB-450 - LIOB-451 - LIOB-452 - LIOB-453 - LIOB-180 - LIOB-181 - LIOB-182 - LIOB-183 - LIOB-184 - LIOB-480 - LIOB-481 - LIOB-482 - LIOB-483 2 Archive Contents ================== File Name Description ------------------------------------------------------------------------------- LIOB-18X_4XX_Readme.txt this file ------------------------------------------------------------------------------- liob_18x_4xx_2_2_3.dl image for firmware upgrade ------------------------------------------------------------------------------- 3 Installation ============== Please first upgrade the Configurator Software to the latest version. The LIOB-18X/4XX Firmware is upgraded by using the LINX Configurator Software. Please refer to the LIOB-18X/4XX user manual for information about firmware upgrade. 4 Changes to Previous Releases ============================== LIOB-18X/4XX 2.2.3 (2012-10-02) ------------------------------- + Upgrades the bootloader to allow updating bigger firmware images. LIOB-18X/4XX 2.2.2 (2012-09-13) ------------------------------- + Fixed a problem which in rare cases could lead to a wrong display of floating point values in the Web UI. LIOB-18X/4XX 2.2.1 (2012-08-13) ------------------------------- + Fixed a problem with uploading the system log from the L-IOB device (LIOB-45X). + Fixed intermediate math results when device is booting (LIOB-X8X). + Fixed CEA-709 scheduler problem with certain custom AST settings (LIOB-X8X). LIOB-18X/4XX 2.2.0 (2012-07-12) ------------------------------- + Added support for LIOB-45X and LIOB-48X devices. ATTN! Upgraded L-IOB hosts (e.g. L-INX devices) need factory reset (once) to support LIOB-45X resp. the LIOB-IP bus. + Allow to reset counting inputs to zero or to new start value in LCD UI. + Fixed a problem with ISO2 STId Card Readers on universal inputs. LIOB-18X 1.1.0 (2012-02-06) --------------------------- + Support of ISO2 STId Card Readers. + Support of fading and ramping for analog outputs. + Bug fix for run hours and energy count persistency. LIOB-18X 1.0.0 (2012-01-11) --------------------------- + Initial Version. -------------------------------------------------- This file is maintained by LOYTEC (www.loytec.com)